CLG

Product Information

NOTE:
If the flow volume of the incoming pressure side is too much, there is a possibility that the proper sequential procedures would not work.
Please use a flow control valve to adjust flow volume from the pressure source.

Usable fluid:
ISO-VG-32 hydraulic oil equivalent to ISO viscosity grade.

Ordering Indication

CLG
3
A
5.0MPa

Product Information

Model CLG-3A CLG-6A
Sequential Action Pressure Adjustment Range(Mpa) 1~6 5~18
Operating Pressure Range(Mpa) 2~35 6~35
Adjusting Screw Turn Ratio(Mpa/Rev) 1 2.8
Cracking Pressure(Mpa) 0.01 0.01
Operating Temperature(°C) 0~+70°C 0~+70°C

File Download